Journal of the Magnetics Society of Japan
Online ISSN : 1880-4004
Print ISSN : 0285-0192
ISSN-L : 0285-0192
Instrument/Magnetics
High Frequency Permeance Measurements Using a Shielded Loop Coil
S. YabukamiM. YamaguchiK. I. Arai
Author information
JOURNAL OPEN ACCESS

1997 Volume 21 Issue 4_2 Pages 813-816

Details
Abstract
We have developed a 1 MHz-2 GHz thin-film permeance meter using a shielded loop-coil type pickup coil. To measure the permeance accurately up to the GHz region, it is necessary to consider impedance matching throughout the driving plates and pickup coil, mode matching of the pickup coil, electromagnetic mode in the driving plates, and the voltage induced by an electric field. Errors can be reduced in the 500 MHz to 2 GHz range by taking account of the change in the input impedance of the pickup coil with and without a magnetic sample.