抄録
The swimming properties of a magnetic micro-machine with a spiral structure were examined experimentally and theoretically under very low Reynolds number conditions. It was demonstrated that the micro-machine could swim in a highly viscous fluid with a Reynolds number of 10-7. This result suggests that the micro-machine has a great potential for medical applications. It was found that the optimum blade shape of the micro-machine varied with the Reynolds number condition.