日本応用磁気学会誌
Online ISSN : 1880-4004
Print ISSN : 0285-0192
ISSN-L : 0285-0192
論文
パターン化磁性リボン被覆ケーブルのノイズ放射特性
森 俊明堀越 伸介神戸 士郎石井 修
著者情報
ジャーナル オープンアクセス

2003 年 27 巻 4 号 p. 590-593

詳細
抄録

We investigated the reliability of cables covered with magnetic ribbons. To simulate the influence of cracks in magnetic ribbons, patterned ribbons (length: X cm) were used to cover the cables. When X equaled the cable length, noise attenuation was 6.8 dB at 120 MHz. As X was decreased to 2 cm, noise attenuation was significantly improved to about 10 dB, which suggests that the resonance of the magnetic ribbon patterns affected noise emission. This fact confirmed that cables covered with magnetic ribbons have high reliability.