Journal of Neuroendovascular Therapy
Online ISSN : 2186-2494
Print ISSN : 1882-4072
ISSN-L : 1882-4072

この記事には本公開記事があります。本公開記事を参照してください。
引用する場合も本公開記事を引用してください。

Evaluation of Stenting for Intracranial Internal Carotid Artery Stenosis Using Flow Reversal
Taku MatsudaKoichi SatohMami HanaokaManabu IshiharaKazuhito Matsuzaki
著者情報
ジャーナル オープンアクセス 早期公開

論文ID: oa.2017-0095

この記事には本公開記事があります。
詳細
抄録

Objective: The safety of stenting for intracranial internal carotid artery stenosis using flow reversal embolic protection was evaluated.

Subjects and Methods: Of the 13 patients who underwent stenting between April 2011 and September 2016, those treated with (group F) and without (group N) flow reversal were compared retrospectively.

Results: An embolic complication was observed in one patient in the group N but none in the group F. The diffusion-weighted imaging (DWI)-positive rate was 0% in the F group.

Conclusion: Stenting for intracranial internal carotid artery stenosis using flow reversal is a safe and effective procedure.

著者関連情報
© 2017 The Japanese Society for Neuroendovascular Therapy

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/