抄録
The analytical treatment of a distributed reactor having spatially dependent parameters is presented. Both the modal expansion method and the function space method are applied successfully to obtain the optimal feedback system for the terminal cost problem. The explicitly posed control obtained by means of the function space method is particularly convenient for machine computation. A numerical example is presented to show the characteristics of the synthesized optimal feedback system.