Journal of Nuclear Science and Technology
Online ISSN : 1881-1248
Print ISSN : 0022-3131
Design of Environmental Monitoring System of Nuclear Facility Based on a Method of Pattern Recognition
Naotake KATOHRyohei KIYOSEYutaka YAMAMOTO
Author information
JOURNAL FREE ACCESS

1977 Volume 14 Issue 10 Pages 737-744

Details
Abstract
The problem to optimize the number and locations of environmental radiation monitoring detectors is formulated by taking the specifically defined distance measures as a performance index and solved numerically using heuristic programming such as branch and bound method. An ideal numerical example neglecting noises due to background radiation and so on shows that the desirable number and locations of detectors are determined mainly by the atmospheric conditions and do not so influenced by the variation of the rate and pattern of activity release from the nuclear facility. It is shown also that the appropriate and sufficient number of monitoring detectors to be located around the facility will be from three to six at most, if considered from the viewpoint of pattern recognition.
Content from these authors

This article cannot obtain the latest cited-by information.

© the Atomic Energy Society of Japan
Previous article Next article
feedback
Top