Journal of Nuclear Science and Technology
Online ISSN : 1881-1248
Print ISSN : 0022-3131
Design of Environmental Monitoring System of Nuclear Facility Based on a Method of Pattern Recognition
Naotake KATOHRyohei KIYOSEYutaka YAMAMOTO
著者情報
ジャーナル フリー

1977 年 14 巻 10 号 p. 737-744

詳細
抄録
The problem to optimize the number and locations of environmental radiation monitoring detectors is formulated by taking the specifically defined distance measures as a performance index and solved numerically using heuristic programming such as branch and bound method. An ideal numerical example neglecting noises due to background radiation and so on shows that the desirable number and locations of detectors are determined mainly by the atmospheric conditions and do not so influenced by the variation of the rate and pattern of activity release from the nuclear facility. It is shown also that the appropriate and sufficient number of monitoring detectors to be located around the facility will be from three to six at most, if considered from the viewpoint of pattern recognition.
著者関連情報

この記事は最新の被引用情報を取得できません。

© the Atomic Energy Society of Japan
前の記事 次の記事
feedback
Top