抄録
Failure analysis was made on samples taken from type 304 stainless steel piping systems (core spray, unloading and feed water pipes) that had cracked in service. In the core spray pipe, large cracks including one penetrating through the wall were found in the upper half of the pipe wall, within the heat-affected zone of the weld joint between the pipe and the nozzle safe end of the reactor pressure vessel. These cracks were of intergranular type, also small transgranular cracks were found beyond the heat-affected zone. Strong correlation was established between the intergranular cracking and severe sensitization in the heat-affected zone.