Journal of Nuclear Science and Technology
Online ISSN : 1881-1248
Print ISSN : 0022-3131
Drop Formation Characteristics in High Speed Agitation of Centrifugal Extractor
Hiromichi FUMOTORyohei KIYOSE
著者情報
ジャーナル フリー

1980 年 17 巻 8 号 p. 627-633

詳細
抄録

For the solvent extraction of reprocessing plant, mixer-settler, pulsed column are op-erated and centrifugal extractor is expected to be used. Mixer-settler has the defect of long contact time. It comes out to cause the solvent damage by radiation in FBR fuel re-processing. In order to escape from the damage, pulse column and centrifugal extractor should be used for FBR spent fuel. However, the characteristics in centrifugal extractor have not yet been fully analyzed, while those of mixer-settler are advanced much. There-fore, the agitation experiment was made to find out the difference of drop formation be-tween mixer-settler and centrifugal extractor. From the results, the average drop diameter is proportional to Weber number to the power of -0.58, when the contact time is long. However, the agitation velocity did not affect the average drop size, when the contact time is less than 11.3 s.

著者関連情報

この記事は最新の被引用情報を取得できません。

© the Atomic Energy Society of Japan
前の記事 次の記事
feedback
Top