1982 年 19 巻 12 号 p. 985-996
Investigations into the flow pattern and the void fraction for countercurrent air-water flow in vertical tubes of diameter D=40 and 80 mm were reported. The flow maps were presented and showed slug flow regime occupied larger portion on them. The void frac-tion was measured by the quick-closing valve technique, in bubbly and slug flow regime.
The void fraction data available in the literatures as well as present work for counter-current flow in vertical tubes were correlated in terms of dimensionless groups. The experimental results of the present work were also compared with the drift flux model.