Journal of Nuclear Science and Technology
Online ISSN : 1881-1248
Print ISSN : 0022-3131
Comparison among Methods for Evaluating Dose Equivalent in Pulsed and Mixed Radiation Field
Keiji ODAHiroshi KOYAMATakayoshi YAMAMOTOMasaharu KAWANISHI
著者情報
ジャーナル フリー

1984 年 21 巻 3 号 p. 224-232

詳細
抄録

In order to ascertain the accuracy and applicability of the method which was developed in the previous paper for evaluating the dose equivalent in a single-burst and mixed radiation field, a comparison with two other ones has been carried out. One is based on the measure-ment of the neutron energy spectrum with TOF system and the separate measurement of the absorbed doses with twin chambers. In the other, a tissue-equivalent proportional counter is used for measuring the LET distribution of the absorbed dose. The average quality factor has been evaluated in a pulsed and mixed field generated by an electron linear accelerator. A good agreement has been found among these methods.
A problem about the experimental determination of the dose equivalent index has also been discussed. It was pointed out that the average quality factor as a function of the depth in tissue could be regarded as characteristic of the mixed radiation field.

著者関連情報

この記事は最新の被引用情報を取得できません。

© the Atomic Energy Society of Japan
前の記事 次の記事
feedback
Top