Journal of Nuclear Science and Technology
Online ISSN : 1881-1248
Print ISSN : 0022-3131
Reliability Analysis of Emergency Decay Heat Removal System of Nuclear Ship under Various Accident Conditions
Comparison between Nuclear Ship "Mutsu" and Nuclear Ship "Savannah"
Takeshi MATSUOKA
著者情報
ジャーナル フリー

1984 年 21 巻 4 号 p. 266-278

詳細
抄録
A reliability analysis is given for the emergency decay heat removal system of the Nuclear Ship "Mutsu" and the emergency sea water cooling system of the Nuclear Ship "Savannah", under ten typical nuclear ship accident conditions. Basic event probabilities under these accident conditions are estimated from literature survey.
These systems of Mutsu and Savannah have almost the same reliability under the normal condition. The dispersive arrangement of a system is useful to prevent the reduction of the system reliability under the condition of an accident restricted in one room.
As for the reliability of these two systems under various accident conditions, it is seen that the configuration and the environmental condition of a system are two main factors which determine the reliability of the system. Furthermore, it was found that, for the evaluation of the effectiveness of safety system of a nuclear ship, it is necessary to evaluate its reliability under various accident conditions.
著者関連情報

この記事は最新の被引用情報を取得できません。

© the Atomic Energy Society of Japan
前の記事 次の記事
feedback
Top