Journal of Nuclear Science and Technology
Online ISSN : 1881-1248
Print ISSN : 0022-3131
Assessment of SAFER03 Code Using ROSA-III Break Area Spectrum Tests on Boiling Water Reactor Loss-of-Coolant Accidents
Seihiro ITOYAHideo NAGASAKAKanji TASAKA
著者情報
ジャーナル フリー

1987 年 24 巻 8 号 p. 639-652

詳細
抄録

The SAFER03 computer code has a newly developed evaluation model for the analysis of various boiling water reactor (BWR) loss-of-coolant accidents (LOCAs). Analyses of the ROSA-IIIbreak area spectrum tests in a recirculation line were performed using the SAFER03 to assess the predictive capability of the code for a BWR LOCA. The ROSA-rn test facility at the Japan Atomic Energy Research Institute (JAERI) was constructed to simulate a LOCA in a BWR/6-251 plant with 848 fuel bundles and 24 jet pumps. This paper summarizes the assessment results of SAFER03 which predicted the system responses and key phenomena well and the conservative peak cladding temperature (PCT) for recirculation line break tests with different break areas.

著者関連情報

この記事は最新の被引用情報を取得できません。

© the Atomic Energy Society of Japan
前の記事 次の記事
feedback
Top