Journal of Oral Science
Online ISSN : 1880-4926
Print ISSN : 1343-4934
ISSN-L : 1343-4934
Original
Comparative evaluation of metal priming agents applied for bonding of magnetic stainless steel with acrylic repair resin
Atsushi Mikami
Author information
JOURNAL FREE ACCESS

2007 Volume 49 Issue 4 Pages 277-281

Details
Abstract

The purpose of this study was to evaluate the effect of acidic priming agents on adhesive bonding to SUS XM27 stainless steel. Disk steel specimens were primed with one of the following materials; Acryl Bond, All-Bond 2 Primer B, Alloy Primer, Estenia Opaque Primer, Eye Sight Opaque Primer, Metal Primer II, M.L. Primer, MR Bond, and Super-Bond Liquid. The specimens were then bonded with an acrylic resin designed for denture repair (Repairsin), and bond strengths were determined. Unprimed specimen was used as control. The average bond strengths before thermocycling varied from 21.3 to 51.0 MPa, whereas post-thermocycling bond strengths ranged from 3.0 to 37.0 MPa. Of the nine priming agents, the Acryl Bond, All-Bond 2 Primer B, Estenia Opaque Primer, and MR Bond materials showed significantly higher bond strength after application of thermocycling. Within the limitation of the current experimental settings, it can be concluded that the use of the four acidic priming agents is recommended for bonding SUS XM27 stainless steel with Repairsin self-polymerizing repair material. (J. Oral Sci. 49, 277-281, 2007)

Content from these authors
© 2007 by Nihon University School of Dentistry
Previous article Next article
feedback
Top