Influence of metal artifacts on in vivo micro-CT for orthodontic mini-implants
Ken-ichiro EjimaSaori OmasaMitsuru MotoyoshiYoshinori AraiYukiko KaiToshihiko AmemiyaHisaya YamadaKazuya HondaNoriyoshi Shimizu
Author information
JOURNAL FREE ACCESS

2012 Volume 54 Issue 1 Pages 55-59

Details
Abstract

This study aimed to show the effects of metal artifacts on the in vivo micro-CT of mini-implants by measuring bone volume. We drilled a hole in the cortical bone of a rat tibia and embedded a titanium orthodontic mini-implant (diameter, 1.5 mm) in the hole. Twelve individually weighed hydroxyapatite grains (HA grains) were placed around the implant either by one dentist (method 1) or separately by 12 dentists (method 2). In vivo micro-CT was used to scan the model after placement of each grain to measure increases and decreases in bone volume voxel number. The subtracted bone voxel volume increased with HA weight in both methods. Simple linear regression analysis showed a significant correlation between weight and volume in both methods (method 1: regression coefficient: 516.502, P < 0.05; method 2: regression coefficient: 4837.432, P < 0.05). Metal artifacts did not appear to influence measurements of bone volume, although further studies are required to determine the effect of thicker implants. (J Oral Sci 54, 55-59, 2012)