Journal of Power and Energy Systems
Online ISSN : 1881-3062
ISSN-L : 1881-3062
Papers
Effects of Optical Loss Factors on Heliostat Field Layout for Beam-Down Solar Concentrating Systems
Motoaki UTAMURATadahiko TAKAMATSUMinoru YUASARina KAJITATakashi YAMAMOTO
Author information
JOURNAL FREE ACCESS

2008 Volume 2 Issue 3 Pages 934-944

Details
Abstract

A methodology to give an optimal layout of a group of heliostats has been developed for beam-down concentrating solar tower systems. Given the maximum solar power together with optical parameters, the method determines an optimal configuration of a heliostat field around a tower. Various optical losses such as cosine factor, shadowing and blocking at heliostats are considered in the calculation. Furthermore, spillage at the receiver is taken into account due to the spread of light caused by the effects of a finite solar disk, flat facet and various stochastic errors in optical hardware and control. It is found the effect of spillage becomes significant at heliostats from the tower at the distance farther than four times of upper focus height of the reflector when receiver diameter is one fifteenth of the height and dominates the configuration of the optimal heliostat layout.

Content from these authors
© 2008 by The Japan Society of Mechanical Engineers
Previous article Next article
feedback
Top