Journal of Prosthodontic Research
Online ISSN : 1883-9207
Print ISSN : 1883-1958
ISSN-L : 1883-1958
Original Articles
Comparison of the accuracy of direct and indirect three-dimensional digitizing processes for CAD/CAM systems – An in vitro study
Bálint VecseiGellért Joós-KovácsJudit BorbélyPéter Hermann
Author information
JOURNAL OPEN ACCESS

2017 Volume 61 Issue 2 Pages 177-184

Details
Abstract

Purpose: To compare the accuracy (trueness, precision) of direct and indirect scanning CAD/CAM methods.

Methods: A master cast with prepared abutments and edentulous parts was created from polymethyl methacrylate (PMMA). A high-resolution industrial scanner was used to create a reference model. Polyvinyl-siloxane (PVS) impressions and digital impressions with three intraoral scanners (iTero, Cerec, Trios) were made (n = 10 for each) from the PMMA model. A laboratory scanner (Scan CS2) was used to digitize the sectioned cast made from the PVS impressions. The stereolithographic (STL) files of the impressions (n = 40) were exported. Each file was compared to the reference using Geomagic Verify software. Six points were assigned to enable virtual calliper measurement of three distances of varying size within the arch. Methods were compared using interquartile range regression and equality-of-variance tests for precision, and mixed-effects linear regression for trueness.

Results: The mean (SD) deviation of short distance measurements from the reference value was −40.3 (79.7) μm using the indirect, and 22.3 (40.0) μm using the direct method. For the medium distance, indirect measurements deviated by 5.2 (SD: 111.3) μm, and direct measurements by 115.8 (SD: 50.7) μm, on average; for the long distance, the corresponding estimates were −325.8 (SD: 134.1) μm with the indirect, and −163.5 (SD: 145.5) μm with the direct method. Significant differences were found between the two methods (p < 0.05).

Conclusions: With both methods, the shorter the distance, the more accurate results were achieved. Virtual models obtained by digital impressions can be more accurate than their conventional counterparts.

Content from these authors

This article cannot obtain the latest cited-by information.

© 2017 Japan Prosthodontic Society

This is an open-access article distributed under the terms of Creative Commons Attribution License 4.0 (CCBY 4.0), which allows users to distribute and copy the material in any format so long as attribution is given to the Japan Prosthodontic Society.
https://creativecommons.org/licenses/by/4.0/
Previous article Next article
feedback
Top