Journal of Prosthodontic Research
Online ISSN : 1883-9207
Print ISSN : 1883-1958
ISSN-L : 1883-1958
Original Articles
Fitness and retentive force of cobalt-chromium alloy clasps fabricated with repeated laser sintering and milling
Mana ToriiToyoki NakataKazuya TakahashiNoboru KawamuraHidemasa ShimpoChikahiro Ohkubo
Author information
JOURNAL OPEN ACCESS

2018 Volume 62 Issue 3 Pages 342-346

Details
Abstract

Purpose: With computer-aided design and computer-aided manufacturing (CAD/CAM), the study was conducted to create a removable partial denture (RPD) framework using repeated laser sintering rather than milling and casting techniques. This study experimentally evaluated the CAM clasp and compared it to a conventional cast clasp.

Methods: After the tooth die was scanned, an Akers clasp was designed using CAD with and without 50 μm of digital relief on the occlusal surface of the tooth die. Cobalt-chromium (Co-Cr) alloy clasps were fabricated using repeated laser sintering (RLS) and milling as one process simultaneously (hybrid manufacturing; HM). The surface roughness of the rest region, gap distances between clasp and tooth die, initial retentive forces, and changes of retentive forces up to 10,000 insertion/removal cycles were measured before and after heat treatment. The HM clasp was compared to the cast clasp and the clasp made by repeated laser sintering only without a milling process.

Results: The HM clasp surface was smoother than those of cast and RLS clasps. With the digital relief, the fitness accuracy of the HM clasp improved. The retentive forces of the HM clasps with relief and after heat treatment were significantly greater than for the cast clasp. HM clasps demonstrated a constant or slight decrease of retention up to 10,000 cycles.

Conclusions: HM clasp exhibited better fitness accuracy and retentive forces. The possibility of clinically using HM clasps as well as conventional cast clasps can be suggested