Journal of Prosthodontic Research
Online ISSN : 1883-9207
Print ISSN : 1883-1958
ISSN-L : 1883-1958
Original Articles
Performance and perception of dental students using three intraoral CAD/CAM scanners for full-arch scanning
Khaled E. AhmedTing WangKar Yan LiWai Kuen LukMichael F. Burrow
Author information
JOURNAL OPEN ACCESS

2019 Volume 63 Issue 2 Pages 167-172

Details
Abstract

Purpose: To assess the average full-arch scanning time, perception and likelihood of future adoption of technology by final-year dental students using three different Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM) intraoral scanning systems.

Methods: Final-year undergraduate Dental Students (FDS), with no prior experience of intraoral scanning, full-arch scanned (IOS) a mannequin head-mounted model under supervision. Three scanning systems were used, TRIOS Colour (TRIOS); True Definition (TDef); and CEREC AC OmniCam (CEREC). Thereafter, FDS completed a questionnaire to assess their perception of IOS. Data were analysed by Generalized Estimating Equations, Fisher's exact tests and logistic regression.

Results: Forty-nine FDS participated. Average full arch IOS time varied significantly (p < 0.001) among the TRIOS, CEREC, and TDef, at 4 min (n = 48), 4 min 42 s (n = 33), and 7 min 32 s (n = 41) respectively. IOS using the TRIOS was significantly (p < 0.001) the quickest, while TDef was the slowest (p < 0.001). Seventy-one percent of FDS had positive overall IOS experience. FDS who reported intraoral scanning was timesaving compared with conventional impressions were more likely to adopt the technology after graduation (odds ratio (OR) = 11.91, 95% confidence interval (CI) = 2.56–55.45, p = 0.002).

Conclusions: Intraoral scanning performance of novice users varied significantly and was dependent on the scanning system used. The questionnaire showed that the overall IOS experience was positive amongst FDS. The perception of time-saving, when using IOS versus conventional impression methods, determined the likelihood of future adoption of the technology.

Content from these authors

This article cannot obtain the latest cited-by information.

© 2019 Japan Prosthodontic Society

This is an open-access article distributed under the terms of Creative Commons Attribution License 4.0 (CCBY 4.0), which allows users to distribute and copy the material in any format so long as attribution is given to the Japan Prosthodontic Society.
https://creativecommons.org/licenses/by/4.0/
Previous article Next article
feedback
Top