Journal of Prosthodontic Research
Online ISSN : 1883-9207
Print ISSN : 1883-1958
ISSN-L : 1883-1958
Original Articles
Three-dimensional trueness analysis of ceramic crowns fabricated using a chairside computer-aided design/manufacturing system: An in vitro study
Seen-Young KangJung-Hyun ParkJi-Hwan KimWoong-Chul Kim
Author information
JOURNAL OPEN ACCESS

2020 Volume 64 Issue 2 Pages 152-158

Details
Abstract

Purpose: This study analyzed the trueness of polymer-infiltrated ceramic and glass ceramic crowns manufactured using the chairside computer-aided design/manufacturing (CAD/CAM) system.

Methods: The master model designs crowns using a CAD program after acquiring a digital impression with an intraoral scanner. Vita Enamic (VE), Vita Suprinity (VS), and IPS e.max CAD (IPS) were used to manufacture 10 crowns each (total: 30 crowns), using the chairside CAD/CAM system (inLab MC XL). Trueness was evaluated by superimposing the CAD data on the scan data using a three-dimensional program. The Kruskal-Wallis H test, a nonparametric test, and the Mann-Whitney U test were performed by applying the significance level (0.05/3 = 0.016), which was adjusted by post-analysis Bonferroni testing.

Results: There was a significant difference in the trueness between the samples (p < 0.05). However, there was no statistically significant difference in the outer surface trueness between the samples (p > 0.05).

Conclusions: These findings show that the milling accuracy of VE is better than that of VS and IPS.

Content from these authors

This article cannot obtain the latest cited-by information.

© 2020 Japan Prosthodontic Society

This is an open-access article distributed under the terms of Creative Commons Attribution License 4.0 (CCBY 4.0), which allows users to distribute and copy the material in any format so long as attribution is given to the Japan Prosthodontic Society.
https://creativecommons.org/licenses/by/4.0/
Previous article Next article
feedback
Top