Abstract

Purpose: To measure the accuracy of the additively manufactured casts with 3 base designs: solid, honeycomb-structure, and hollowed bases.

Methods: A virtual cast was used to create different base designs: solid (S Group), honeycomb-structure (HC group), and hollowed (H group). Three standard tessellation language files were used to fabricate the specimens using a material jetting printer (J720 Dental; Stratasys) and a resin (VeroDent MED670; Stratasys) (n=15). A coordinate measuring machine was selected to measure the linear and 3D discrepancies between the virtual cast and each specimen. Shapiro-Wilk test revealed that all the data was not normally distributed (P<.05). Kruskal Wallis and Mann Whitney U tests were used (α=.05).

Results: The S group obtained a median ±interquartile range 3D discrepancy of 53.00 ±73.25 µm, the HC group of 58.00 ±67.25 µm, and the H group of 34.00 ±45.00 µm. Significant differences were found in the x- (P<.001), y- (P<.001), and z-axes (P<.001), and 3D discrepancies among the groups (P<.001). Significant differences were found between the S and H groups (P=.002) and HC and H groups (P<.001) on the x-axis; S and H groups (P<.001) and HC and H groups (P<.001) on the y-axis; S and H groups (P<.001) and HC and H groups (P<.001) on the z-axis; and S and H groups (P<.001) and HC and H groups (P<.001) on the 3D discrepancy.

Conclusion: The base designs influenced on the accuracy of the casts but all the specimens obtained a clinically acceptable manufacturing range. The H group obtained the highest accuracy.

Content from these authors
© 2022 Japan Prosthodontic Society

This is an open-access article distributed under the terms of Creative Commons Attribution-NonCommercial License 4.0 (CC BYNC 4.0), which allows users to distribute and copy the material in any format as long as credit is given to the Japan Prosthodontic Society. It should be noted however, that the material cannot be used for commercial purposes.