Journal of Prosthodontic Research
Online ISSN : 1883-9207
Print ISSN : 1883-1958
ISSN-L : 1883-1958
Case report
Intraoral scanner and computer-aided design/manufacturing technology for the fabrication of double-crown-retained removable dental prosthesis: A clinical report
Akinori Tasaka Takahiro ShimizuShuichiro Yamashita
Author information
JOURNAL OPEN ACCESS

2022 Volume 66 Issue 3 Pages 519-523

Details
Abstract

Patient: This clinical report describes treatment with a double-crown-retained removable dental prosthesis fabricated using an intraoral scanner (IOS) and computer-aided design/manufacturing technology (CAD/CAM). A 68-year-old female patient presented with complaints of missing maxillary right first and left second premolars. CAD/CAM technology was applied to plan treatment with a double-crown-retained removable dental prosthesis. The patient consented to this treatment option but did not want orthodontic treatment for the anterior crossbite of the right side. After the definitive preparation of the abutment teeth, the shape of the provisional restoration was adjusted to match the definitive prosthesis. An IOS was used to obtain digital scans of the provisional restoration, occlusion, antagonist arch, and prepared surface of the abutment teeth. First, the primary crowns were milled from cobalt-chromium alloy. Next, using an intraoral scanner, a pick-up impression of the primary crowns was performed, and the secondary crowns were designed, milled, and veneered. After delivery, the patient expressed satisfaction with the functionality, esthetics, and fit of the double-crown-retained removable dental prosthesis.

Discussion: The surface of the primary crowns was coated with scan spray when the pick-up impression was made using the IOS. Practice is needed to achieve a thin and homogeneous coating with scan spray to improve reproducibility.

Conclusion: Double-crown-retained removable dental prostheses can be successfully fabricated using an IOS and CAD/CAM technology, resulting in patient satisfaction.

Content from these authors
© 2022 Japan Prosthodontic Society

This is an open-access article distributed under the terms of Creative Commons Attribution-NonCommercial License 4.0 (CC BY-NC 4.0), which allows users to distribute and copy the material in any format as long as credit is given to the Japan Prosthodontic Society. It should be noted however, that the material cannot be used for commercial purposes.
https://creativecommons.org/licenses/by-nc/4.0/
Previous article Next article
feedback
Top