Journal of Prosthodontic Research
Online ISSN : 1883-9207
Print ISSN : 1883-1958
ISSN-L : 1883-1958
Original articles
Accuracy of the preparation depth in mixed targeted restorative space type veneers assisted by different guides: An in vitro study
Jing GaoTian LuoYuwei ZhaoChenyang XieHaiyang Yu
Author information
JOURNAL OPEN ACCESS

2023 Volume 67 Issue 4 Pages 556-561

Details
Abstract

Purpose: Most veneers are mixed targeted restorative space (MTRS)-type restorations that are partially within the original tooth and require inconsistent preparation depths. This study aimed to evaluate the accuracy of the preparation depth for MTRS veneer preparation.

Methods: MTRS veneer preparation models were developed using the twisted maxillary central incisor (MCI) as the original tooth and the standard MCI as the waxing. Veneer preparations were performed using freehand (MF), silicone (MS), thermoplastic (MT), 3D-printed uniform (MD), and auto-stop (MA) guides. The prepared and original MCI were scanned and superimposed using a custom-made base. The mean absolute differences (MADs) were measured to evaluate the accuracy of the preparation depth. Statistical analysis was performed using the multivariate analysis of variance (MANOVA) test (α=0.05).

Results: The accuracy of the preparation depth was 0.237±0.090, 0.191±0.099, 0.149±0.078, 0.093±0.050, and 0.059±0.040 mm in MF, MS, MT, MD, and MA, respectively. The MADs between the groups were significant (P<0.05). The accuracy of the trial restoration was 0.140±0.081 mm in the MS, and the accuracy of the guiding tube was 0.055±0.033, 0.036±0.011, and 0.033±0.010 mm in the MT, MD, and MA, respectively.

Conclusions: In MTRS veneer preparation for MCI, tooth preparation guides improved the accuracy of the preparation depth by visualizing the TRS profile and providing clear measurement points. The accuracy of the guide is influenced by its flexibility, and the accuracy of the preparation depth is affected by the accuracy of the measurement points.

Content from these authors
© 2023 Japan Prosthodontic Society

This is an open-access article distributed under the terms of Creative Commons Attribution-NonCommercial License 4.0 (CC BYNC 4.0), which allows users to distribute and copy the material in any format as long as credit is given to the Japan Prosthodontic Society. It should be noted however, that the material cannot be used for commercial purposes.
https://creativecommons.org/licenses/by-nc/4.0/
Previous article Next article
feedback
Top