Journal of Prosthodontic Research
Online ISSN : 1883-9207
Print ISSN : 1883-1958
ISSN-L : 1883-1958
Original articles
Effect of build orientation on the wear resistance and hardness of denture teeth fabricated using digital light processing: An in vitro study
Khin Pyae SoneHidekazu TakahashiMaiko Iwaki Sahaprom NamanoYuriko KomagamineShunsuke MinakuchiManabu Kanazawa
Author information
JOURNAL OPEN ACCESS

2024 Volume 69 Issue 2 Pages 267-274

Details
Abstract

Purpose: This in vitro study investigated the effect of build orientation on the wear resistance and hardness of denture teeth fabricated using digital light processing (DLP) compared to other denture tooth materials.

Methods: Disc-shaped specimens were prepared using denture tooth monomers and DLP devices in three build orientations: 0°, 45°, and 90°. Specimens of the same shape were fabricated using denture tooth materials for subtractive manufacturing, commercially available polymethylmethacrylate (PMMA) resin, and composite resin. The wear resistance was evaluated as the wear volume loss after 50,000 wear cycles using a ball-on-disc wear device in water for two-body wear and poppy seed slurry for three-body wear. The Vickers hardness values of the materials were measured. Two-way and one-way analyses of variance were performed for wear resistance and hardness, respectively, followed by Tukey’s honest significance test.

Results: The interaction between the denture tooth resins and maximum wear volume was significant (P < 0.01). The 0° build orientation exhibited the lowest wear volume in the three-body wear test and the highest hardness among the three build orientations. The 0° DLP-fabricated specimens demonstrated significantly less wear volume than that of the PMMA specimens and a wear volume comparable to that of the milled specimens. However, the 0° DLP-fabricated specimens showed significantly lower hardness than that of the milled and PMMA specimens. The composite resin specimens exhibited the highest wear resistance and hardness.

Conclusions: A 0° build orientation is recommended for DLP-fabricated denture teeth compared to 45° and 90° orientations to achieve greater wear resistance and hardness.

Fullsize Image
Content from these authors
© 2025 Japan Prosthodontic Society

This is an open-access article distributed under the terms of Creative Commons Attribution-NonCommercial License 4.0 (CC BYNC 4.0), which allows users to distribute and copy the material in any format as long as credit is given to the Japan Prosthodontic Society. It should be noted however, that the material cannot be used for commercial purposes.