Journal of Prosthodontic Research
Online ISSN : 1883-9207
Print ISSN : 1883-1958
ISSN-L : 1883-1958
Original articles
The clinical performance of CAD/CAM-fabricated hybrid ceramic restorations in cases with severe wear: A 3-year clinical trial
Tsung-Chieh Yang , Chun-Min Shen, Hsin-Chou Chen, Chih-Chun Tseng
Author information
JOURNAL OPEN ACCESS

2026 Volume 70 Issue 2 Pages 250-258

Details
Abstract

Purpose: To evaluate the clinical use of CAD/CAM hybrid ceramics in patients with severe tooth wear.

Methods: Forty-nine patients with severe tooth wear underwent prosthetic management with 116 hybrid ceramic restorations. The restorations were evaluated at 1 week and at 3, 6, 12, 18, 24, 30, and 36 months after placement. The amount of wear on the restorations, antagonist teeth, and opposite teeth was compared using digital superimposition analysis. A questionnaire was used to evaluate participants’ satisfaction with the restorations. Complications were recorded, and survival rates were estimated using Kaplan–Meier analysis.

Results: The clinical performance of the restorations was stable for esthetic, functional, and biological parameters up to 3 years, except for greater changes in “surface and margin staining” and “fracture and retention.” There was no significant difference in the amount of progressive wear among the restorations, antagonist teeth, and opposite side teeth until 18 months; however, the wear on the restorations increased gradually up to 36 months. Higher scores and identical satisfaction results were obtained for the chewing efficiency and cleanability during the observation period. The most common complications were restoration dislodgement (5.2%) and partial marginal chipping (4.3%), which were clinically repaired. Four restorations (3.4%) were extensively fractured and replaced. The estimated survival rate of the hybrid ceramic restorations at 3 years was 88.0%.

Conclusions: The clinical use of hybrid ceramic restorations in patients with severe tooth wear improved chewing efficiency and esthetics, provided adequate resistance for load-bearing, and delivered a stable treatment outcome after functional use.

Content from these authors
© 2025 Japan Prosthodontic Society

This is an open-access article distributed under the terms of Creative Commons Attribution-NonCommercial License 4.0 (CC BYNC 4.0), which allows users to distribute and copy the material in any format as long as credit is given to the Japan Prosthodontic Society. It should be noted however, that the material cannot be used for commercial purposes.
https://creativecommons.org/licenses/by-nc/4.0/
Previous article Next article
feedback
Top