Journal of Prosthodontic Research
Online ISSN : 1883-9207
Print ISSN : 1883-1958
ISSN-L : 1883-1958

This article has now been updated. Please use the final version.

Considerations for the selection of interim restoration materials using wear test results
Takuya KiharaTomoko IkawaYuko Shigeta Shuji ShigemotoKeisuke IharaKeita SasakiKentaro HiraiTakumi Ogawa
Author information
JOURNAL OPEN ACCESS Advance online publication

Article ID: JPR_D_20_00103

Details
Abstract

Purpose: The purpose of this study was to examine the wear of resin materials using two-body wear tests and to verify a selection method for optimal interim restoration materials from findings of a diagnostic occlusal dev ice.
Methods: Specimens were prepared from nine different resins used for diagnostic occlusal devices (soft resin) and interim restorations. Wear tests were conducted using an abrasion testing machine. The resulting wear on resin specimens and antagonist stainless-steel styluses was measured using a laser confocal scanning microscope, and the surface conditions were observed through a scanning electron microscope. The data were analyzed with one-way ANOVA and Tukey’s multiple comparison test. The findings of the previous study on diagnostic occlusal devices were referred to in order to verify the selection method of optimal interim restoration materials.
Results: The maximum wear depth of the soft resin specimens was significantly greater than that of the other specimens (p<0.05) and was equivalent to the wear depth of a diagnostic occlusal device used for 14 nights. The wear of bis-acryl resin material was shallower than that of the other materials (Polymethyl methacrylate and polyethyl methacrylate), and its antagonist stylus was significantly worn (p<0.05).
Conclusions: The findings of the previous and present studies showed a relationship among the parameters of Electromyography, wear depth of the diagnostic occlusal device, and wear of materials used for interim restorations. Findings related to bruxism can guide in the selection of interim restoration material and the determination of a suitable duration of wear.

Content from these authors

この記事はクリエイティブ・コモンズ [表示 - 非営利 4.0 国際]ライセンスの下に提供されています。
This is an open-access article distributed under the terms of Creative Commons Attribution-NonCommercial License 4.0 (CC BY-NC 4.0), which allows users to distribute and copy the material in any format as long as credit is given to the Japan Prosthodontic Society. It should be noted however, that the material cannot be used for commercial purposes.
https://creativecommons.org/licenses/by-nc/4.0/deed.ja