Measuring peri-implant bone lesions using low-dose cone-beam computed tomography
Laura Christine Leisner Akinori TasakaCharlotte Theresa TrebingTim HilgenfeldMatthias Adalbert KosinskiDorothea KronsteinerPeter RammelsbergFranz Sebastian Schwindling
Author information
JOURNAL OPEN ACCESS Advance online publication

Article ID: JPR_D_20_00110

Details
Abstract

Purpose: High-definition cone-beam computed tomography (HD-CBCT) offers superior image quality at the cost of higher radiation dose compared to low-dose CBCT (LD-CBCT). The aim of this study was to investigate whether peri-implant bone lesions can be accurately quantified using LD-CBCT, even when including the influence of surrounding tissues.
Methods: Twelve titanium implants restored with all-ceramic crowns were placed in bovine bone, and peri-implant lesions were prepared. Radiographic imaging was performed using IR (intraoral radiography), HD-CBCT and LD-CBCT. To simulate the in-vivo situation, the samples were placed inside a dry human mandible, and a second LD-CBCT imaging was performed (LD-CBCT*). The datasets were presented to four observers in random order. Maximum lesion depth and width were measured in a standardized mesiodistal slice in IR, HD-CBCT, LD-CBCT, and LD-CBCT*. Mean lesion depth and width measurements for each sample in HD-CBCT served as reference.
Results: Interrater agreement was slight for depth and excellent for width in HD-CBCT and both LD modes. For all observers, measurement deviations from HD-CBCT were below 0.3 mm in the LD protocols (LD-CBCT depth: 0.22 ± 0.17 mm, width: 0.22 ± 0.13 mm; LD-CBCT* depth: 0.24 ± 0.23 mm, width: 0.25 ± 0.21 mm) and at 0.4 mm in IR.
Conclusions: Absolute differences between LD-CBCT and HD-CBCT are small, although surrounding tissues decrease LD-CBCT image quality. Within the limitations of an in-vitro trial, LD-CBCT may become an adequate imaging modality for monitoring peri-implant lesions at a substantially decreased radiation dose.

Content from these authors

この記事はクリエイティブ・コモンズ [表示 - 非営利 4.0 国際]ライセンスの下に提供されています。
This is an open-access article distributed under the terms of Creative Commons Attribution-NonCommercial License 4.0 (CC BY-NC 4.0), which allows users to distribute and copy the material in any format as long as credit is given to the Japan Prosthodontic Society. It should be noted however, that the material cannot be used for commercial purposes.