Journal of Prosthodontic Research
Online ISSN : 1883-9207
Print ISSN : 1883-1958
ISSN-L : 1883-1958

This article has now been updated. Please use the final version.

Single mandibular implant study – chewing efficiency – 5-year results from a randomized clinical trial using two different implant loading protocols
Nicole Passia Shurouk AliChristoph BehrendtElfriede FritzerRalf Joachim KohalRalph G. LuthardtNadine Frfr. v. MaltzahnMichael RädelDaniel R. ReissmannFranz Sebastian SchwindlingStefan WolfartMatthias Kern
Author information
JOURNAL OPEN ACCESS Advance online publication

Article ID: JPR_D_21_00216

Details
Abstract

Purpose: To investigate the chewing efficiency of edentulous patients wearing complete dentures, treated with a single implant in the mandible, placed underneath the existing mandibular dentures, using two different loading protocols (immediate loading or conventional loading), over an observation period of 5 years.

Methods: One-hundred and fifty-eight (158) edentulous seniors aged 60-89 years received an implant in the midline of the lower jaw and were randomized either to the immediate loaded group A (n=81) or the conventional loaded group B (n=77). Chewing efficiency was obtained before treatment, one month after implant placement during the submerged healing phase (only group B) and 1, 4, 12, 24 and 60 months after implant loading.

Results: After 5 years, chewing tests from 89 patients (45 in the immediate loading group and 44 in the conventional loading group) were available for every recall visit and thus statistically analyzed. The chewing efficiency increased over time in both groups. A significant increase was observed up to 4 months after loading (p≤0.05). Later, chewing efficiency further increased, but not significantly. Between the two loading protocols, chewing efficiency did not differ significantly (p>0.05) at any follow-up investigation.

Conclusion: A single mandibular implant placed underneath existing mandibular dentures improves chewing efficiency of edentulous patients significantly over an observation period of 5 years, irrespective of the loading protocol.

Content from these authors
© 2022 Japan Prosthodontic Society

This is an open-access article distributed under the terms of Creative Commons Attribution-NonCommercial License 4.0 (CC BYNC 4.0), which allows users to distribute and copy the material in any format as long as credit is given to the Japan Prosthodontic Society. It should be noted however, that the material cannot be used for commercial purposes.
https://creativecommons.org/licenses/by-nc/4.0/
feedback