Journal of Prosthodontic Research
Online ISSN : 1883-9207
Print ISSN : 1883-1958
ISSN-L : 1883-1958
Outcomes of surveyed monolithic CAD/CAM zirconia crowns for removable partial denture abutments: A 7-year clinical study
Ahmed M Aziz Hiba AlshaibahAdam Bin Husein
Author information
JOURNAL OPEN ACCESS Advance online publication

Article ID: JPR_D_24_00183

Details
Abstract

Purpose: This retrospective clinical study aimed to evaluate the clinical outcomes of surveyed monolithic computer-aided design and computer-aided manufacturing (CAD/CAM) zirconia crowns for abutment teeth in removable partial dentures (RPDs).

Methods: Patients who received monolithic surveyed zirconia crowns were clinically examined. The crowns were examined according to the modified United States Public Health Service criteria, and Kaplan-Meier survival was determined. The effect of different variables on the survival and success rates was assessed using Cox regression analysis (α = 0.05).

Results: A total of 297 crowns of 275 patients were evaluated over a mean period of 7 years. The cumulative survival and success rates were 95.6% and 91.2%, respectively. Complications were in the form of secondary caries (n=12), minor chipping (n=9), and debonding (n=5). A higher number of failures was observed in the mandibular molars (P < 0.05).

Conclusions: Surveyed monolithic zirconia crowns demonstrated high survival after 7 years of service. Monolithic zirconia is an excellent alternative to metal ceramic crowns for RPD abutments.

Content from these authors
© 2025 Japan Prosthodontic Society

This is an open-access article distributed under the terms of Creative Commons Attribution-NonCommercial License 4.0 (CC BYNC 4.0), which allows users to distribute and copy the material in any format as long as credit is given to the Japan Prosthodontic Society. It should be noted however, that the material cannot be used for commercial purposes.
https://creativecommons.org/licenses/by-nc/4.0/
Previous article Next article
feedback
Top