Abstract

Purpose: This was a prospective study conducted alongside a randomized controlled trial (RCT) that evaluated the incidence of fractures and associated risk factors in single-implant overdentures (1-IOD) compared with two-implant overdentures (2-IOD).

Methods: The participants received either a mandibular 1-IOD or 2-IOD (attachments: Straumann® retentive anchor and elliptical titanium matrix with gold insert; implants: 4.1 mm diameter, Straumann® Standard Plus SLActive® Regular Neck), within the context of a randomized clinical trial. The primary outcome of interest was the incidence of IOD fractures at 5-year follow-up. Prosthetic factors, such as area and cervico-incisal height in the attachment region, and volume at the inter-canine region, were measured. Patient-related factors including age, sex, handgrip strength, manual dexterity, bite force, and chewing performance were assessed. Data analysis included descriptive statistics, bivariate tests, Kaplan-Meier plots, and linear discriminant analysis with log10 transformation for variable normalization.

Results: A total of 47 patients were recruited, and 34 (n = 34, 1-IOD = 16, 2-IOD = 18; mean-age: 63.9 ± 8.6 years; 79.4% women) completed the 5-year follow-up. There were no differences in the incidence of fractures between the 1-IOD and 2-IOD groups (P < 0.05). Fractures were more frequent in younger patients, and reduced cervico-incisal IOD height was significantly associated with fractures (P = 0.040). Linear discriminant analysis predicted fractures with 84.4% accuracy and identified cervico-incisal height and age as key predictors.

Conclusions: There were no significant differences in the incidence of overdenture fractures between groups. Reduced cervico-incisal denture height in the attachment region of ball-retained IODs was associated with mandibular IOD fractures. Further studies with larger cohorts are recommended to identify additional risk factors for mandibular IODs.

Content from these authors
© 2025 Japan Prosthodontic Society

This is an open-access article distributed under the terms of Creative Commons Attribution-NonCommercial License 4.0 (CC BYNC 4.0), which allows users to distribute and copy the material in any format as long as credit is given to the Japan Prosthodontic Society. It should be noted however, that the material cannot be used for commercial purposes.