Abstract

Purpose: We evaluated the effects of the particle size and content of surface pre-reacted glass-ionomer (S-PRG) filler on the mechanical properties and antimicrobial efficacy of a hard denture relining material.

Methods: S-PRG microfiller (0.8–1 μm; 5, 10, and 20 wt%) and nanofiller (0.3–0.5 μm; 2.5, 5, and 10 wt%) were incorporated into a Shofu denture liner. The control group did not contain S-PRG fillers. The surface morphology (scanning electron microscopy), roughness (confocal scanning laser microscopy; Shapiro–Wilk’s test followed by Dunnett or Steel’s test), ion release after 24 h immersion in ultrapure water (fluoride, aluminum, borate, sodium, silicate, strontium ions; Shapiro–Wilk’s test followed by one-way ANOVA with Tukey’s test or Kruskal–Wallis and Dunn’s tests), three-point flexural strength (Weibull analysis), shear bond strength after 24 h water immersion or 10,000 thermal cycles (linear mixed-effects model), and antimicrobial activity against Candida albicans (confocal microscopy, Shapiro–Wilk’s test followed by Dunnett’s or Steel’s test) were analyzed and compared. The significance level was set at α = 0.05.

Results: Although a higher S-PRG filler content reduced the flexural and bond strengths, it increased the surface roughness and ion release. Groups treated with 10 wt% nanofiller or 20 wt% microfiller displayed significantly inhibited C. albicans adhesion. The nanofiller-containing groups maintained flexural strength comparable to that of the control.

Conclusions: The incorporation of 10 wt% S-PRG nanofiller provided the best balance between antimicrobial efficacy and mechanical performance, indicating that this formulation may be clinically acceptable for use in hard denture relining materials.

Content from these authors
© 2026 Japan Prosthodontic Society

This is an open-access article distributed under the terms of Creative Commons Attribution-NonCommercial License 4.0 (CC BYNC 4.0), which allows users to distribute and copy the material in any format as long as credit is given to the Japan Prosthodontic Society. It should be noted however, that the material cannot be used for commercial purposes.