日本薬理学会年会要旨集
Online ISSN : 2435-4953
WCP2018 (The 18th World Congress of Basic and Clinical Pharmacology)
セッションID: WCP2018_PO1-13-4
会議情報

Poster session
Selection of spinal needles for cerebrospinal fluid collection in clinical trials
Tatsuya YoshiharaKoki FurushoYukikuni SakataHiroshi TsukikawaRyuzo HanadaRie YazawaTakeshi ChiyodaIppei IkushimaShunji MatsukiShin Irie
著者情報
会議録・要旨集 オープンアクセス

詳細
抄録

Background:

The need of cerebrospinal fluid (CSF) collection is increasing in psychoactive drug development. Postdural puncture headache (PDPH) is the most common complication after the procedure. Thinner needles and/or non-cutting needles (called pencil-point or Sprotte needle) are often used to prevent PDPH. But obtaining necessary amount of CSF is also crucial in clinical trials. Generally, thinner needles need more time to collect CSF than thicker needles, therefore selection of needles is a key factor for successful trials. In this study, we retrospectively analyzed the outlet speed of CSF by needle type.

Methods:

The data of 44 volunteers (age, 70 ± 4; male, 59%) who underwent CSF collection from September 2016 to December 2017 at SOUSEIKAI Fukuoka Mirai Hospital were analyzed. We changed the needle types to prevent headaches: first, we used 21G non-cutting (Quincke) needles, then changed to 22G Quincke needles, and we now use 22G pencil-point needles for elderly volunteers.

Results:

21 G Quincke needles were used for 26 volunteers and 22G needles for 18 volunteers (Quincke needles for 6 and pencil-point needles for 12). Although mean BMI was higher in the 21G group than the 22G group (23.7 ± 2.0 vs 21.9 ± 3.0, p=0.02), time from local anesthesia to CSF outflow start was not different between the 21G and 22G groups (3.7 ± 3.1 vs 3.7 ± 1.7 min, respectively). The CSF outflow speed was faster in the 21G group than the 22G group (2.0 ± 0.5 vs 1.3 ± 0.3 mL/min, respectively, p<0.0001). Types of needle in the 22G group (Quincke or pencil-point needle) did not affect the outflow speed (1.3 ± 0.4 vs 1.3 ± 0.3 mL/min, respectively). Two volunteers (6%) had headaches and 2 (6%) had heaviness of head in the Quincke needle group, but no volunteer (0%) had headaches or heaviness of head in the pencil-point needle group.

Conclusions:

CSF outflow speed was slower with thinner needle. To prevent PDPH and obtain required amount of CSF, needle type should be carefully selected based on the amount of necessary CSF, acceptable time in lateral position for volunteers and the incidence rate of complication.

著者関連情報
© 2018 The Authors(s)
前の記事 次の記事
feedback
Top