Journal of Physical Therapy Science
Online ISSN : 2187-5626
Print ISSN : 0915-5287
ISSN-L : 0915-5287
Original Articles
Comparison of Cardiopulmonary Function Changes during Wheelchair Propulsion: Backrest Angle
Soo-Young Chae
著者情報
ジャーナル フリー

2012 年 24 巻 4 号 p. 355-357

詳細
抄録
[Purpose] Changes in cardiopulmonary function during wheelchair propulsion on a treadmill were measured using wheelchairs according to backrest angle adjustment. [Methods] Twenty-two healthy male subjects were the subjects. Oxygen consumption (VO2, ml/min), heart rate (HR, beats/min), carbon dioxide emissions (VCO2, ml/min), oxygen uptake per body weight (VO2, ml/kg/min), and respiration frequency (Rf) were used as the measurement variables for cardiopulmonary data. [Results] The peak value, average value and value at rest were compared. When resting, the value did not differ except for VO2, and the peak value, did not differ except for VCO2. However, the average value in all except VO2/kg (at 13 degrees) was significantly lower than 3 degrees (93°). [Conclusion] A 13° wheelchair backrest angle (103°) provides a lower cardiopulmonary workload than the base angle (3°). A training program for good seating and posture needs to be provided
著者関連情報
© 2012 by the Society of Physical Therapy Science
前の記事 次の記事
feedback