Journal of Radiation Research
Online ISSN : 1349-9157
Print ISSN : 0449-3060
REGULAR PAPERS
Treatment Planning for Heavy-ion Radiotherapy: Biological Optimization of Multiple Beam Ports
MICHAEL KRÄMER
著者情報
ジャーナル フリー

2001 年 42 巻 1 号 p. 39-46

詳細
抄録
A crucial task in radiotherapy is dose conformation to the prescribed target volume whilst sparing the surounding healthy tissue around as much as possible. One of the best approaches so far is active dose shaping in three dimensions using scanned beams of charged particles, like carbon ions. Besides their inverse dose profile and minimal lateral scattering, carbon ions have the advantage that their RBEs increase towards the end of their range. An active beam-delivery system for intensity-modulated carbon-ion beams has been operational at GSI since December, 1997. In order to ensure dose conformation, inverse treatment planning with respect to the biologically effective dose distribution must be applied. A typical patient irradiation comprises two singly optimized opposing fields. This paper discusses the superposition of biologically effective dose distributions for radiotherapy with 12C ions, which is non-trivial due to the nonlinear nature of the dose response of biological systems. Sum rules for the nonlinear addition of singly optimized fields are derived. This method is being used clinically, and has been successfully applied to more than 50 patients.
著者関連情報

この記事は最新の被引用情報を取得できません。

© 2001 by Journal of Radiation Research Editorial Committee
前の記事 次の記事