Journal of Radiation Research
Online ISSN : 1349-9157
Print ISSN : 0449-3060
Supplement
Calculation of the Absorbed Dose for the Overexposed Patients at the JCO Criticality Accident in Tokai-mura
NOBUHITO ISHIGUREAKIRA ENDOYASUHIRO YAMAGUCHIKIYOMITSU KAWACHI
Author information
JOURNAL FREE ACCESS

2001 Volume 42 Issue SUPPL Pages S137-S148

Details
Abstract
The doses for the overexposed patients were estimated by the measurement result of specific activity of 24Na in blood. The present method is almost based on documents of the International Atomic Energy Agency (IAEA) and the Oak Ridge National Laboratory. The neutron energy spectrum obtained using the ANISN code (Multigroup One-Dimensional Discrete Ordinates Transport Code System with Anisotropic Scattering) was assumed. The values in ICRP Publication 74 were applied for the doses in each organ per unit neutron fluence. Gamma-ray dose was indirectly estimated based on (a) the result of environmental monitoring around the accident site and (b) a graph in IAEA manual, which gives the kerma ratio of neutrons and γ-rays as a function of the critical volume or the atomic ratio of hydrogen to 235U. The estimated neutron doses were 5.4 Gy for patient A, 2.9 Gy for patient B and 0.81 Gy for patient C. The estimated γ-ray doses were 8.5 or 13 Gy for patient A, 4.5 or 6.9 Gy for patient B, and 1.3 or 2.0 Gy for patient C.
Content from these authors

This article cannot obtain the latest cited-by information.

© 2001 by Journal of Radiation Research Editorial Committee
Previous article Next article
feedback
Top