Journal of Radiation Research
Online ISSN : 1349-9157
Print ISSN : 0449-3060
Measurement of 131I in the Human Thyroid Gland Using a NaI (T1) Scintillation Survey Meter
田中 義一郎河村 曰佐男
著者情報
キーワード: Thyroid, 131I, Monitoring
ジャーナル フリー

1978 年 19 巻 1 号 p. 78-84

詳細
抄録
As a method of prompt and rapid estimation of thyroidal 131I burden of the public (and nuclear workers) in emergency exposure to radioiodine, feasibility of a use of a scintillation survey meter with a NaI (T1) crystal was demonstrated using phantoms simulating the thyroid gland of Japanese.
Age dependency in the efficiency of detection was found. From the obtained detection limit, a possibility of the practical application of this method was proven. The present method may be safely used in rapid screening and measurement to a first approximation of the thyroidal 131I burden and consequently approximation of absorbed dose to the thyroid gland in emergency situations.
著者関連情報

この記事は最新の被引用情報を取得できません。

© Japan Radiation Research Society