日本AEM学会誌
Online ISSN : 2187-9257
Print ISSN : 0919-4452
ISSN-L : 0919-4452
特集 第26回「電磁力関連のダイナミクス」シンポジウム
広範囲に均一な回転磁界を発生する磁粉探傷磁化装置の開発
福岡 克弘川越 一平尾崎 智裕岩田 成弘粂田 昌彦及川 芳朗
著者情報
ジャーナル フリー

2015 年 23 巻 1 号 p. 118-124

詳細
抄録
The maximum magnetic flux leakage from a crack is obtained when the direction of the magnetic flux is orthogonal to the longitudinal direction of the crack. In magnetic-particle testing with a yoke method, since we usually cannot predict the direction of the crack to be detected, it is necessary to perform the testing at least two times by changing the direction of magnetization. In a rotating magnetic field type magnetizer using three-pole coils (three-phase alternating current), omnidirectional crack can be detected by a single testing. However, directions of the weak magnetic flux density appear at positions far from the center of the magnetizer, and the rotating magnetic field becomes no homogeneous distribution. In this research, it was considered to split each magnetic pole in the magnetizer to generate the uniform rotating magnetic field. The distribution of the rotating magnetic flux density was evaluated with a finite element method analysis, and an optimal disposition angle of the split coil was discussed. In addition, a multi coil magnetizer was developed to generate the uniform rotating magnetic field more widely.
著者関連情報
© 2015 日本AEM学会
前の記事 次の記事
feedback