回転磁界を用いた立体形状部における全方向傷の磁粉探傷試験の検討と探傷性能評価
福岡 克弘
著者情報
ジャーナル フリー

2020 年 28 巻 2 号 p. 63-68

詳細
抄録

 The maximum magnetic flux leakage from a crack is obtained when the magnetic flux is distributed orthogonally towards the crack; thus, clear magnetic particle indications are formed, which enables accurate inspection of cracks via magnetic particle testing (MT). However, cracks may be overlooked in a complex 3D shape because a magnetizer often cannot be configured to the complex portion being inspected and the test object cannot be appropriately magnetized.

 In this study, the MT with a rotating magnetic field was executed for an H-shaped test object replicating a complex mechanical part, and the flaw detection performance in its complex shape portions was evaluated. Additionally, distributions of rotating magnetic flux density in a test object were analyzed with the finite element method. The analytical results and the actual magnetic particle testing results were compared.