Abstract
When the sampling data number of 1 cycle is decreased, an indicated mean effective pressure calculation error from pressure diagram increases. This factor is effect of aliasing by the decrease of sampling data number. It is verified on steady operation conditions that error reduction can be performed by excluding this effect. In this paper, verification by transient operation was performed and good result was obtained like steady operation.