人工臓器
Online ISSN : 1883-6097
Print ISSN : 0300-0818
ISSN-L : 0300-0818
装着型人工腎臓装置の改良
―透析液循環ポンプ及び透析液保温システム等の改良―
瀬尾 真一大坪 修堀内 孝葛原 敬八郎杉本 久之高井 信治高橋 浩稲生 綱政
著者情報
ジャーナル フリー

1981 年 10 巻 1 号 p. 64-67

詳細
抄録
A Wearable Artificial Kidney ( gross weight; 7kg) which has the possibility of clinical trial has been developed in our laboratory. Main improvement of the device are a dialysate pump, a reservoir and a dialysate warming system. This dialysate pump was 30% smaller in size and with 50% saving in weight as compared to conventional one. Because the reservoir is made of hard materials (polypropylene), the increase in level of liquid surface reveals volume of removed water. In regard to the dialysate warming system, bodywarmers and a patient's temperature were used as the sources of heat. We assembled the device consisting of these and tried in vivo experiments. An anephric dog was maintained under stable condition by this system for about three weeks. As the result of in vivo experiments, it seems that this system will be applied to a clinical trial.