人工臓器
Online ISSN : 1883-6097
Print ISSN : 0300-0818
ISSN-L : 0300-0818
KINETICS OF MANGANESE TRANSPORT IN CHRONIC HEMODIALYSIS PATIENTS
SHINICHI HOSOKAWAHIROSHI NISHITANITADAO TOMOYOSHIOSAMU YOSHIDA
著者情報
ジャーナル フリー

1987 年 16 巻 2 号 p. 838-841

詳細
抄録
Manganese (Mn) transport and dialysance during hemodialysis were examined in fifteen chronic hemodialysis patients. Serum Mn levels in fifteen volunteer outpatients tended to increase after 5-hour dialysis; (0.20±0.06μg/dl before HD; 0.25±0.06 after HD). Serum Mn levels were 0.64±0.12μg/dl in normal subjects. The increase was mainly due to hemoconcentration evidenced by a significant increase in the hematocrit during HD. To study the changes resulting from diffusion, we measured Mn in the arterial blood and in the dialysate at the inflow and outflow sites of the dialyzer. Mn diffused across the dialyzer from the blood to the dialysate in fifteen cases. Mn dialysance of 15 patients was-48.6±71.7ml/min. The relationship between ultrafiltrable Mn levels and serum Mn levels before HD was a significant correlation (r=0.69, p<0.005).
著者関連情報
© The Japanese Society for Artificial Organs
前の記事 次の記事
feedback
Top