人工臓器
Online ISSN : 1883-6097
Print ISSN : 0300-0818
ISSN-L : 0300-0818
Pacemaker植え込み患者におけるdigitalisの左室収縮時間に及ぼす影響それを左右する因子
松浦 雄一郎山科 秀機新田素 弘大谷 博滝沢 伊津夫三島 斉外尾 明利
著者情報
ジャーナル フリー

1975 年 4 巻 6 号 p. 363-368

詳細
抄録
Twelve patients who had been implanted artificial pacemaker for the treatment of bradycardia due to atrioventricular block, S.S.S. and atrial fibrillation were studied to determine the respone to digitalis in the resting position using mechanocardiogram. The ejection time, isometric contraction time, preejection period and Q-SII interval shortened following digitalis administration. There was not found significant relationship between the changes in ejection time and preejection period. The degree of shortening of ejection time was more remarkable in the elder patient and/or with diastolic hypertension, while the degree of shortening of preejection period was more remarkable in the catient with S.S.S and atrial fibrillation and/or normotension.
It is considered that the results obtained in this study were produced by complicated consequences including an increased force and velocity of the cardiac contraction, increased peripheral arterial resistance and increased cardiac output due to digitalis, and probably underlying disease.
著者関連情報
© 一般社団法人 日本人工臓器学会
前の記事 次の記事
feedback
Top