Jinko Zoki
Online ISSN : 1883-6097
Print ISSN : 0300-0818
ISSN-L : 0300-0818
Studies of enzyme treated heterograf is as arterial substitutes
Conparative study on methods of enzyme treatment and their tensile strength test
H. SAITO
Author information
JOURNAL FREE ACCESS

1977 Volume 6 Issue 2 Pages 88-92

Details
Abstract
The tensile strength of treated bovine grafts was comparatively evaluated regarding to enzyme used, its activating time and tanning method.
A quality of enzyme was not a significant factor and the only difference was related to its activation time. As a result nynhidrin test, tensile test and histological analysis, activation time of 2 1/2 hours was considered to be appropriate in 1% ficin and 3 1/2 hours in 1.5% papain. As for the tanning agents, neo-chrome was relatively superior to others in terms of flexibility. No difference was observed between glutar aldehyde and formaldehyde.
Content from these authors
© The Japanese Society for Artificial Organs
Previous article Next article