人工臓器
Online ISSN : 1883-6097
Print ISSN : 0300-0818
ISSN-L : 0300-0818
拍動流中および一定圧流下での平織テトロン人工血管の漏水特性
大内 博佐々木 久雄横堀 寿光横堀 武夫斎藤 武雄前山 俊秀大熊 恒郎葛西 森夫
著者情報
ジャーナル フリー

1979 年 8 巻 3 号 p. 396-401

詳細
抄録

New experimental apparatus has been developed simulated of wind-kessel theory as a elastic model of arterial system. That is, the relation of the repeating frequency, the amount of flow, resistance of valve and the compliance of the specimen, to maximum pressure, minimum pressure and the pressure difference in this developed apparatus was experimentally proved to be similar to the relation of the cardiac frequency, cardiac output, peripheral resistance and the compliance of artery, to systolic pressure, diastolic pressure and pulse pressure in artery system, respectively.
Using this apparatus, the characteristics of water leakage through the vascular substitute of woven Tetron was studied under pulsating, constant and combined pulsating and constant pressure, respectively.
These experimental results show non-steady effect of water, say, pulsatiled pressure, is significant factor of leakage characteristics from vascular substitute. Some other effects are also studied. Furthermore hydrodynamical model of leakage characteristics has been proposed and shown in good agreement with experimental characteristics.

著者関連情報
© 一般社団法人 日本人工臓器学会
前の記事 次の記事
feedback