Japanese Journal of Clinical Chemistry
Online ISSN : 2187-4077
Print ISSN : 0370-5633
ISSN-L : 0370-5633
Simultaneous Determination of Chlorpromazine and Levomepromazine in Human Plasma by High-Performance Liquid Chromatography Using Electrochemical Detection
KOJI MURAKAMIKAZUO MURAKAMITADATAKA UENOJUNKO HIJIKATAKIMIO SHIRASAWATOSHITAKE MUTOH
Author information
JOURNAL FREE ACCESS

1982 Volume 11 Issue 1 Pages 50-55

Details
Abstract
A rapid, selective and sensitive method for the simultaneous determination of chlorpromazine (CPZ) and levomepromazine (LPZ) in human plasma has been developed using high-performance liquid chromatograph with electrochemical detector.
The unchanged drugs and internal standard extracted from plasma were separated by a reversed-phase high-performance liquid chromatography and the separation was completed within 10 min. The influences of acetonitrile concentration and of the pH of the mobile phase were investigated. The minimum detectable amounts were 100pg for CPZ and LPZ, respectively. In comparison with other three detection systems this was found to be the most sensitive method.
This method was applied to the simultaneous determination of CPZ and LPZ in human plasma.
Content from these authors
© Japan Society of Clinical Chemistry
Previous article Next article
feedback
Top