連続フロー分析による血清総胆汁酸の測定
武田 立守吉田 滋織田 佳代子広瀬 信吾
著者情報
ジャーナル フリー

1984 年 13 巻 3 号 p. 134-139

詳細
抄録
A highly sensitive fluorescence assay for total bile acid in serum using a flow injection system is described.
The applrltus consists of six-port valve, pretreatment column (2×20mm) packed serumout-25 (Sekisui chemical co.), immobilized enzyme column (3α-hydroxysteroid dehydrogenase, 3α-HSD, 2×30mm), injector, peristaltic pump and fluorescence detector.
This system enables to detect total bile acid from serum injection directly without sample pretreltment.The new device is especially useful for clinical studies where total bile acid has to be determined from serum.Moreover, the method was more sensitive and simple than conventional method.(cv=1.99%, n=10).