Doboku Gakkai Ronbunshu
Online ISSN : 1882-7187
Print ISSN : 0289-7806
ISSN-L : 0289-7806
APPLICATION OF RESIN LINING SYSTEM FOR COUNTERMEASURES FOR PREVENTING LEAKAGE FROM OPENINGS IN LOW TEMPERATURE MATERIALS STORAGE
Yoshinori InadaShozo Seki
Author information
JOURNAL FREE ACCESS

1996 Volume 1996 Issue 554 Pages 259-268

Details
Abstract
In the case of low temperature materials storage in openings excavated in rock mountain, such as LNG, LPG and frozen food etc., cracks occurs around openings by shrinkage of rock mass have been shown. Also in the cases a “water curtain system” and an “ice lining system” for countermeasure for preventing leakage of gas and liquid from the openings have been proposed. In this study, as another method a “resin lining system” was proposed, physical properties of resin at low temperature were obtained by the test. From the results of the stress analysis using these value, it was found that by the lining of resin make independent with rock, that is the “resin lining system” is an effective way to prevent leakage of gas and liquid from the openings.
Content from these authors
© by Japan Society of Civil Engineers
Previous article
feedback