日本複合材料学会誌
Online ISSN : 1884-8559
Print ISSN : 0385-2563
ISSN-L : 0385-2563
研究論文
アコースティックエミッション測定を用いた炭素繊維強化プラスチックス接着継手の健全性評価手法の検討
小林 訓史山田 廣之長田 稔子
著者情報
ジャーナル フリー

2020 年 46 巻 4 号 p. 137-142

詳細
抄録

In this study, we used the acoustic emission (AE) method to evaluate the integrity of a carbon fiber-reinforced plastic (CFRP) single-lap joint. We fabricated single-lap joints with different adherends, surface roughness and contamination conditions. For these joints, AE measurements were conducted under tensile shear adhesion strength tests to investigate the possibility of evaluating the state of adhesion. The shear adhesion strength for unidirectional CFRP was higher than that for textile CFRP. Surface roughening effectively improved the strength and contamination degraded the strength at the tips of the joint. AE measurement results suggested the possibility of integrity monitoring for CFRP joints by focusing on whether the Kaiser effect is effective.

著者関連情報
© 2020 日本複合材料学会
前の記事 次の記事
feedback
Top