主催: 一般社団法人日本太陽エネルギー学会
会議名: 2025年度(令和7年度)研究発表会
開催地: 明治大学 駿河台キャンパス リバティータワー
開催日: 2025/11/02 - 2025/11/03
p. 67-70
A 6-year operational analysis was conducted on the solar water heating system installed at the convention center. The results showed an average solar fraction of approximately 10%. The recorded solar heat utilization amount was less than half of the estimated collector heat collection, indicating significant heat loss in the collector piping. Furthermore, the storage tank is operating at half its design capacity, which is also considered to be suppressing the thermal collection.