日本リウマチ・関節外科学会雑誌
Online ISSN : 1884-9059
Print ISSN : 0287-3214
ISSN-L : 0287-3214
Spinal Instrument for the Lumber Spine in Rheumatoid Arthritis
Naoya TAJIMAKohichi MATSUMOTOKohichi TASHIROShigeru KUWAHARAChihiro KIMURATohyo MAEHALA
著者情報
ジャーナル フリー

1989 年 8 巻 2 号 p. 205-212

詳細
抄録
Six patients with rheumatoid lumbar spine involvement underwent instrumentation surgery and are reported on. Five patients were in stage 4 and one in stage 3. The preoperative symptoms were lumbago (5 cases), paresis of the lower extremities (4 cases), disturbance of urinary bladder and rectum function (2 cases) and intermittent claudication (1 case) . Roentgenograms showed osteoporosis (6 cases) and compression fracture or collapse (5 cases) . The instruments used for surgery were Mizuno's spinal plate (2 cases), Luque wiring (1 case), a segmental square spinal instrument (2 cases) and ceramics (1 case) . After surgery stable fixation of the spine was obtained in all cases.
著者関連情報
© Japanese Society for Joint Diseases